Project:
Magnet-Assembly Installation Cell
Company:
Philips Oral Healthcare
Description:
Design of a system to install magnetic sub-assemblies onto a brush head assembly.

The sub-assembly is bonded to the assembly using a cyanoacrylate adhesive.  Before bonding, the adhesion site is prepared with a primer.  The adhesive is then dispensed, and verified with a machine vision system. Finally, the sub-assembly is installed onto the main assembly, and verified using a force-gage.